Termofol Antifreeze Cable TF-CW-SR6m

Description

The Termofol TF-CW-SR6m is a self-regulating heating cable designed to protect water pipes and pipelines from freezing. This cable automatically adjusts its heating power based on the ambient temperature, providing constant and efficient protection without the need for a separate thermostat.

Technical Specifications:

Characteristic Specification
Model TF-CW-SR6m
Length 6 meters
Assets 60 W/m
Supply voltage 230V 50/60 Hz
Maximum operating temperature +65°C
Minimum installation temperature -25°C
Minimum bending radius 3.5 times the cable diameter
Protection class IPX8
Application Pipes up to 2" diameter

Key Features:

  • Self-regulating: The cable automatically adjusts its power based on the ambient temperature, increasing energy efficiency and preventing overheating.
  • Easy installation: Suitable for both internal and external installation on pipes, without the need for a separate thermostat.
  • Safety: Approved for contact with drinking water, making it ideal for drinking water pipes in, for example, summer houses or seasonal homes.

Installation tips:

  1. Preparation: Make sure the pipe to be protected is clean and dry.
  2. Installation methods:
    • Internal to pipe: Prevents interference with existing thermal insulation; ideal for buried pipes.
    • Externally on the pipe under insulation: Recommended when the pipe is not yet insulated.
  3. Fixing: Secure the cable securely with suitable tape or fasteners to prevent shifting.
  4. Insulation: Cover the pipe and cable with suitable thermal insulation to minimize heat loss.
  5. Connection: The cable comes with a 2.5 meter long power cable for easy connection to the mains.

Applications:

  • Residential buildings: Protection of water pipes in unheated areas or outdoors.
  • Commercial Buildings: Prevent freezing in pipes and pipelines in warehouses or industrial facilities.
  • Agriculture: Protection of irrigation systems and water tanks against frost damage.

By using the Termofol TF-CW-SR6m self-regulating heating cable, you can effectively prevent pipes from freezing, ensuring reliable operation and reducing maintenance costs.

Product form

The Termofol TF-CW-SR6m is a self-regulating heating cable designed to protect water pipes and pipelines from freezing. This cable automatically... Read more

SKU: TF-CW-SR6M

€71,07 Incl. VAT

    Specifications

    • Format: 10mm x 6 meters
    • Voltage: 230 Volt
    • Wattage: 60 Watt
    • Color: Black
    • Weight: 0.6 kg
    • Suitable for m²:
    • Protection: IPX8
    • Surface temperature:
    • Montage:

      Description

      The Termofol TF-CW-SR6m is a self-regulating heating cable designed to protect water pipes and pipelines from freezing. This cable automatically adjusts its heating power based on the ambient temperature, providing constant and efficient protection without the need for a separate thermostat.

      Technical Specifications:

      Characteristic Specification
      Model TF-CW-SR6m
      Length 6 meters
      Assets 60 W/m
      Supply voltage 230V 50/60 Hz
      Maximum operating temperature +65°C
      Minimum installation temperature -25°C
      Minimum bending radius 3.5 times the cable diameter
      Protection class IPX8
      Application Pipes up to 2" diameter

      Key Features:

      • Self-regulating: The cable automatically adjusts its power based on the ambient temperature, increasing energy efficiency and preventing overheating.
      • Easy installation: Suitable for both internal and external installation on pipes, without the need for a separate thermostat.
      • Safety: Approved for contact with drinking water, making it ideal for drinking water pipes in, for example, summer houses or seasonal homes.

      Installation tips:

      1. Preparation: Make sure the pipe to be protected is clean and dry.
      2. Installation methods:
        • Internal to pipe: Prevents interference with existing thermal insulation; ideal for buried pipes.
        • Externally on the pipe under insulation: Recommended when the pipe is not yet insulated.
      3. Fixing: Secure the cable securely with suitable tape or fasteners to prevent shifting.
      4. Insulation: Cover the pipe and cable with suitable thermal insulation to minimize heat loss.
      5. Connection: The cable comes with a 2.5 meter long power cable for easy connection to the mains.

      Applications:

      • Residential buildings: Protection of water pipes in unheated areas or outdoors.
      • Commercial Buildings: Prevent freezing in pipes and pipelines in warehouses or industrial facilities.
      • Agriculture: Protection of irrigation systems and water tanks against frost damage.

      By using the Termofol TF-CW-SR6m self-regulating heating cable, you can effectively prevent pipes from freezing, ensuring reliable operation and reducing maintenance costs.

      Recently viewed products

      Login

      Forgot your password?

      Don't have an account yet?
      Create account